- Up to 400 AMPS -48VDC
- Hot-Swap Rectifiers
- Intelligent Digital Controller
- Front Panel Visual Displays
- 8 Breakers
- Load Bus 50mV, 400A shunt for each
- 510AH
Battery Autonomy
- Disconnect Levels 400A
|
- Up to 600 AMPS -48VDC
- Hot-Swap Rectifiers
- Intelligent Digital Controller
- 1 or 3 Phase Input
- Front Panel Visual Displays
- 12 Breakers
- 50mV, 600A shunt for each
- 510AH
Battery Autonomy
- Disconnect Levels 600A
|
| |
|
Click here for datasheet
Click here for manual
|
Click here for datasheet
Click here for manual
|
------------------------------------------------------------- |
------------------------------------------------------------- |
|
HOT-SWAP RECTIFIERS - WALL MOUNTED RECTIFIERS - RACK MOUNT POWER SHELVES
|
| |
- 1U or 2U, 19" or 23" Rack-Mount
- -400C to +700C Operation
- Low Fan Noise
- Class B Conducted EMI
- DC Good LED
- Universal 85 to 264VAC Input
- Active Power Factor Correction
- 0.99 Power Factor
- Output Voltage: 12 to 54.4VDC
- Up to 92% Efficiency
- ORing Diode on Output
- Hot-Swappable
|
Call us NOW for immediate delivery!
|
|
|
| |
| |
|
| |
| |
|
- RSF: 7.4A at 54.4V, 12.9A at 27.2V, 22.1A at 13.6V
- RSG: 10.1A at 54.4V, 18.4A at 27.2V, 33.0A at 13.6V
- RSJ: 12.0A at 54.4V
- TSF: 8.3A at 48V, 14.7A at 24V, 25.0A at 12V
- TSG: 11.5A at 48V, 20.8A at 24V, 37.5A at 12V
- TSJ: 13.6A at 48V
|
| |
Click here for datasheet
|
------------------------------------------------------------- |
|
HOT-SWAP RECTIFIERS & SHELVES |
|
|
|
|
| |
|
|
|
| |
|
- 1U High
- 19-Inch Shelf
- Up to 54A at 48V, 83A at 24V, 150A at 12V
- RSF: 7.4A at 54.4V, 12.9A at 27.2V, 22.1A at 13.6V
- RSG: 10.1A at 54.4V, 18.4A at 27.2V, 33.0A at 13.6V
- RSJ: 12.0A at 54.4V
- TSF: 8.3A at 48V, 14.7A at 24V, 25.0A at 12V
- TSG: 11.5A at 48V, 20.8A at 24V, 37.5A at 12V
- TSJ: 13.6A at 48V
|
- 1U HIgh
- 19-Inch Shelf
- RPCG: 8A at 54.4V, 15A at 27.2V, 27A at 13.6V
- RPCM: 15A at 54.4V, 25A at 27.2V, 45A at 13.6V
- RPCP: 22A at 54.4V, 33A at 27.2V, 50A at 13.6V
- RPCQ: 25A at 54.4V
- TPCG: 9.4A at 48V, 16.7A at 24V, 30.8A at 12V
- TPCM: 16.7A at 48V, 29.2A at 24V, 54.2A at 12V
- TPCP: 25.0A at 48V, 41.7A at 24V, 66.7A at 12V
|
| |
|
Click here for datasheet
Click here for manual
|
Click here for datasheet
Click here for manual
|
------------------------------------------------------------- |
------------------------------------------------------------- |
| |
|
|
|
|
|
| |
|
- RBSR48/37: 37.0A at 54.4VDC
- RBSR24/60 *: 60.0A at 27.2VDC
- RBSR12/100: 100.0A at 13.6VDC
- TBSR7000: 42.0A at 48.0VDC
- TBSR5000 *: 60.0A at 24.0VDC
- TBSR3000: 100.0A at 12.0VDC
|
- 19-Inch Shelf: Up to 150A at 54.4V, 300A at 27.2V or 13.6V
- 23-Inch Shelf: Up to 200A at 54.4V, 400A at 27.2V or 13.6V
- RRPI: 25A at 54.4V, 50A at 27.2V, 100A at 13.6V
- RRSI: 50A at 54.4V, 100A at 27.2V
|
| |
|
| * AVAILABLE 2nd HALF 2009 |
|
Click here for datasheet
|
Click here for datasheet
Click here for manual
|
------------------------------------------------------------- |
------------------------------------------------------------- |
|
Click here to see a range of batteries recommended for use with our rectifiers. |
|
| |
|
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
- Up to 9,000 Watts Output Power
- 19-Inch Shelf: 28-32VDC at 6,750W
- 23-Inch Shelf: 28-32VDC at 9,000W
- 85% Efficiency
- Power Factor Correction to EN61000-3-2
- 10.6W/In³ Power Density
- Hot-Swap 2U
- 26.5-33.5V Output Adjustment Range
- 28 to 32VDC Rated Output
- 2250W Module Output Power
- Up to 9000W Total Power, Non-Redundant
- Up to 6750W Total Power, 3+1 Redundant
- Integral Isolation Diode
|
|
| |
Click here for datasheet
|
|
|
POWER DISTRIBUTION PANELS |
|
| |
- 1U or 2U, 19" or 23" Rack-Mount
- Single Bus or Dual Bus (A/B)
- Operating Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
- Fuse Panels 80-150A per Bus
- Breaker Panels 150-300A per Bus
- Low Voltage Disconnects 70-600A per Bus
|
Call us NOW for immediate delivery! |
1U High Rack-Mount Fuse Panels |
|
|
|
|
|
- GMT Fuses
- All Connections Made at the Front
- Single Bus, 4 or 6 Fuses
- Dual Bus (A/B), 4 or 6 Fuses per Bus
- Bus Capacity: 80A per Bus
- Fuses rated from 1/2A to 20A
- Operating Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
|
- GMT Fuses
- Single Bus with 10or 20 Fuses
- Dual Bus (A/B) with 10 Fuses per Bus
- Bus Capacity: 80A per Bus
- Fuses rated from 1/2A to 12A
- Operating Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
|
| |
|
Click here for datasheet
|
Click here for datasheet
Click here for manual
|
---------------------------------------------------------------- |
---------------------------------------------------------------- |
|
|
|
|
- GMT Fuses
- All Connections Made at the Front
- Single Bus, 4 or 6 Fuses
- Dual Bus (A/B), 4 or 6 Fuses per Bus
- Bus Capacity: 80A per Bus
- Fuses rated from 1/2A to 20A
- Operating Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
|
- GMT Fuses
- Single Bus with 10 Fuses
- Dual Bus (A/B) with 10 Fuses per Bus
- Bus Capacity: 80A per Bus
- Fuses rated from 1/2A to 12A
- Operating Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
|
| |
|
Click here for datasheet
|
Click here for datasheet
|
---------------------------------------------------------------- |
---------------------------------------------------------------- |
| |
Rack-Mount Breaker Panels |
|
|
|
|
|
- Magnetic Circuit Breakers
- Single Bus with 6 Breakers
- Dual Bus (A/B) with 6 Breakers per Bus
- Bus Capacity: 150A per Bus
- Breakers rated from 1A to 50A
- Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
|
- Magnetic Circuit Breakers
- Single Bus with 4 Breakers
- Dual Bus (A/B) with 4 Breakers per Bus
- Bus Capacity: 50A per Bus
- Breakers rated from 5A to 50A
- Voltage: 120 or 230VAC
- NEMA (120VAC only) or Screw Terminal Load Connections
|
| |
|
Click here for datasheet
Click here for manual
|
Click here for datasheet
Click here for manual
|
---------------------------------------------------------------- |
---------------------------------------------------------------- |
|
|
|
|
|
- Magnetic Circuit Breakers
- Dual Bus (A/B) with 9 Breakers per Bus
- Bus Capacity: 300A per Bus
- Breakers rated from 1A to 100A
- Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
|
| |
Click here for datasheet
Click here for manual
|
|
Rack-Mount Combination Panels |
| |
|
|
| |
|
|
|
| |
- Dual Section (A/B)
- Current Capacity per Section: 60A to 150A
- Operating Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
- A & B are Isolated Loads
- Combination of Fuses, Breakers, LVD
- GMT, KTK or Type 70 Fuses
- 1A to 50A Circuit Breakers
- LVD has Battery Circuit Breaker
- LVD in Series with Battery or Load
|
| |
Click here for datasheet
|
---------------------------------------------------------------- |
Click here to see a range of batteries recommended for use with our rectifiers. |
|
|
|
| |
- 19" or 23" Rack-Mount
- 1RU and 2RU High
- Single or Dual (A/B) LVDs
- Form C Relay Contacts
- N+1 Parallel Operation
- LVD in Series with Battery or Load
- Low Voltage Disconnects
- Positive or Negative Ground
|
Call us NOW for immediate delivery! |
|
|
|
|
|
| |
|
- One Mounting Position High: 1.75”
- 19- or 23-Inch Rack Mounting
- Single or Dual (A/B) LVDs
- Current Capacity: 70A per Load
- Operating Voltage: 24 or 48VDC
- Positive or Negative Ground
- Red LED Alarm
- Form C Relay Contacts
- LVD in Series with Battery or Load
- Battery Circuit Breaker:100A
- LVD Bypass Switch, Optional
- Rack Offset Every ¼”, Front to Back
- Low Voltage Disconnects
|
- One Mounting Position High: 1.75”
- 19- or 23-Inch Rack Mounting
- Current Capacity: 200A
- Operating Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
- Red LED Alarm
- Form C Relay Contacts
- LVD in Series with Battery or Load
- Rack Offset Every ¼”, Front to Back
- Low Voltage Disconnects
|
| |
|
Click here for datasheet
Click here for manual
|
Click here for datasheet
|
----------------------------------------------------------------
|
----------------------------------------------------------------
|
|
|
|
| |
- Two Mounting Position High: 3.5”
- 19- or 23-Inch Rack Mounting
- Single or Dual (A/B) LVDs
- Current Capacity: 400A or 600A per Load
- Operating Voltage: 24 or 48VDC
- Positive or Negative Ground
- Form C Relay Contacts
- LVD in Series with Battery or Load
- Field Settable Disconnect & Reconnect Voltages
- Low Voltage Disconnects
|
| |
Click here for datasheet
Click here for manual |
 |
|
POWER CONTROL& MONITORING SYSTEMS, 1U High |
| |
|
|
|

|
|
- Basic Power Controller
- 19- or 23-Inch Rack Mounting
- Positive or Negative Polarity
- Reverse Polarity Protected
- 48 or 24VDC Versions
- Up to 16 Rectifiers
- Float Voltage Adjust
- Voltage Adjust Option
- Battery Temp. Compensation Option
- Optional Digital Voltmeter and Ammeter Panel
- 8 LED Alarm Indicators
- Form C Relay Contact Alarm
|
- Remote Access Power Controller
- Controls up to 64 Rectifiers
- Controls LV Disconnects
- Local or Remote Monitoring
- Ethernet Communications
- 12, 24 or 48VDC Operation
- I²C Rectifier Monitoring & Control
- Front Panel or Web-Based Programming
- 16-Character, 2-line LCD Display
- 8-Key Touchpad Control
- 16 LED Indicators
- Form C Relay Alarms
|
|
|
Click here for datasheet
Click here for manual
|
Click here for datasheet
Click here for manual
|
| |
|
---------------------------------------------------------------- |
---------------------------------------------------------------- |
|
DC to DC CONVERTER SYSTEMS |
| |
DC to DC Converter Systems |
TPCM Q48 Series: |
|
|
|
- 48VDC to 12 or 24VDC
- Includes Isolated 5V, ¼A Standby Output
- Hot-Swap Operation
- Wide Range 40 to 60VDC Input
- Integral LED Status Indicators
- I2C Serial Data Bus Option
- Up to 8.8 Watts/Cubic Inch Power Density
- Low Profile: 1.6 Inches (41mm) High
- Single Hot-Swappable Connector
- Reverse Air Flow Option
- Staged Pin Engagement
- ORing Diode on Output
|
- Includes Isolated 5V, ¼A Standby Output
- Hot-Swap Modules
- 48 or 54.4VDC Output
- Wide Range 20 to 30VDC Input
- Integral LED Status Indicators
- 12.5 Watts/Cubic Inch Power Density
- Low Profile: 1.6 Inches (41mm) High
- Single Hot-Swappable Connector
- Remote Output Adjustment
- Staged Pin Engagement
- ORing Diode on Output
- 1U, 19” Rack Holds 3 Units
- Active Current Sharing
|
| |
|
Click here for datasheet
Click here for manual
|
Click here for datasheet
Click here for manual
|
---------------------------------------------------------------- |
---------------------------------------------------------------- |
Click here to see a range of batteries recommended for use with our rectifiers. |
|
|
| |
- 1U, 2U, & 5U 19" or 23" Rack-Mount
- Hot-Swap Inverter Modules
- AC Load Distributions
- Static Transfer Switch
- N+1 Parallel Operation
- SNMP Option
- Controller / Remote Access
- Manual Bypass
- Parallelable
|
Call us NOW for immediate delivery! |
|
|
|
|
|
- 12V, 24V or 48VDC Input
- 115VAC or 230VAC Output
- Only 1RU High
- Static Transfer Function
- 1000 or 2000 VA
- 50 or 60Hz Low Distortion Sine Wave
- 90% Typical Efficiency
- Powers Reactive Loads
- LED Status Display
|
- 48VDC to 120 or 230VAC
- Only 1RU High, 19-Inch Shelf
- N+1 Parallel Operation
- Parallellable to 18kVA
- 50 or 60Hz Low Distortion Sine Wave
- Scalable to 12kVA at 120VAC or 18kVA at 230VAC
- Fully Isolated from Battery Input
- DSP Management & Control
|
| |
|
Click here for datasheet
Click here for manual
|
Click here for datasheet
Click here for manual
|
-------------------------------------------------------------------- |
-------------------------------------------------------------------- |
|
|
|
|
|
- 48VDC to 115 or 230VAC
- Ultra-Compact
- 2RU High, 19-Inch Shelf
- N+1 Redundant Operation
- Systems to 30kVA
- Hot-Swap Replacement in Shelves
- AC Distribution Panel Available
- Fully Isolated from Battery Input
|
- 1RU High 19- or 23-Inch Rack Mounting
- 92% Efficiency Rectifiers
- Isolated A/B Sections
- Up to 8 Circuit Breakers
- Common or Isolated A & B Sections
- AC Breaker Capacities: 5A to 30A
- Up to 4 Inverter Inputs
- AC Circuit Breaker Panels
|
| |
|
Click here for datasheet
Click here for 5U datasheet
|
Click here for datasheet
Click here for manual
|
-------------------------------------------------------------------- |
-------------------------------------------------------------------- |
|
|
| |
|
|
|
|
|
| |
|
- 48VDC to 115 or 230VAC
- Up to 5 Paralleled Inverters
- Built-In AC Distribution
- 5RU-High, 23-Inch Shelf
- Parallelable Shelves
|
- 48VDC to 115 or 230VAC
- 19-inch or 23-inch Rack Mount
- Controller, STS, SNMP Comms
- Systems to 18kVA
- Ultimate Power Density
- System Status Display
- AC Load Distribution
|
| |
|
Click here for datasheet
Click here for manual
|
Click here for datasheet
Click here for manual
|
-------------------------------------------------------------------- |
-------------------------------------------------------------------- |
|
|
|
- Up to 15kVA, 3 Shelves
- Only 2RU High
- Easy Connections
- Attaches to INV2500
|
| |
Click here for datasheet
|
-------------------------------------------------------------------- |
Click here to see a range of batteries recommended for use with our rectifiers. |
|
|